Nghiên cứu xác định điều kiện gây nổ bầu không khí mỏ khi vận hành mạng điện hạ áp 660 V trong mỏ hầm lò

https://mij.hoimovietnam.vn/en/archives?article=170610
  • Affiliations:

    Hanoi University of Mining and Geology

  • *Corresponding:
    This email address is being protected from spambots. You need JavaScript enabled to view it.
  • Received: 15th-Mar-2017
  • Revised: 22nd-Sept-2017
  • Accepted: 10th-Dec-2017
  • Online: 31st-Dec-2017
Pages: 40 - 42
Views: 16
Downloads: 0
Rating: , Total rating: 0
Yours rating

Abstract:

The article presents the results of a study to determine the time conditions to prevent the spark energy arised by the single phase leakage current, when the gap appears into the ground loop of a low-voltage 660V underground network and it can detonate the mine atmosphere in order to find solutions for ensuring explosion safety in the operation of these low-voltage networks.

How to Cite
Tien, N.Hanh 2017. Nghiên cứu xác định điều kiện gây nổ bầu không khí mỏ khi vận hành mạng điện hạ áp 660 V trong mỏ hầm lò (in Vietnamese). Mining Industry Journal. XXXI, 6 (Dec, 2017), 40-42. .
References

1. A.A, Каймаков, B.C. Торгашов, с.A. Песок, ГЕ. Кашицын, МА Васнев, Взрывобезопасность рудничного электрооборудования, Издательство Недра Москва 1982.

2. Nguyễn Hanh Tiến. Nghiên cứu phòng ngừa nổ khí mỏ do dòng điện của các mạng điện xoay chiều ở các mỏ than hầm lò Quảng Ninh. Luận án Tiến sĩ kỹ thuật. Trường Đại học Mỏ - Địa chất. Hà Nội 2005.

3. Nguyễn Hanh Tiến, Ngô Thanh Tuấn và nnk. Nghiên cứu điều kiện an toàn nổ khí mỏ do dòng điện rò gây ra trong các mạng điện hạ áp xoay chiều mỏ than hầm lò vùng Quảng Ninh. Báo cáo tổng kết đề tài Khoa học và Công nghệ cấp Bộ. Hà Nội 2011.

4. QCVN 01:2011/BCT. Quy chuẩn kỹ thuật Quốc gia về an toàn trong khai thác than hầm lò. Hà Nội 2011.

4. QCVN 01:2011/BCT. Quy chuẩn kỹ thuật Quốc gia về an toàn trong khai thác than hầm lò. Hà Nội 2011.

Other articles